ABSTRAK
Air limbah domestik umumnya yang berasal dari suatu kegiatan komersial atau
Perumahan, Restoran, Kantor, Apartemen dan asrama biasanya dihasilkan dari
kegiatan manusia. Pada awalnya, air limbah di Jakarta hanya dibuang langsung ke
sungai atau saluran air tanpa pengolahan terlebih dahulu. Hal ini disebabkan karena
masih minimnya fasilitas pengolahan air buangan kota (sewerage system), sehingga
mengakibatkan tercemarnya badan-badan sungai (Said, 2020). Glodok Plaza
Jakarta berada di wilayah komersial dan merupakan pusat perbelanjaan yang
terletak di daerah Jakarta Barat sehingga merupakan salah satu tempat penghasil air
limbah domestik yang cukup besar. Air limbah domestik yang ada di Glodok Plaza
bersumber dari toilet atau wastafel cuci tangan, hotel dari kamar mandi dan dapur
makanan, serta Food Court dari dapur makanan yang kemudian air limbah tersebut
diolah agar hasil buangan tidak mencemari lingkungan. Pada bulan Januari 2023
parameter amonia memiliki nilai sebesar 9 mg/l berdasarkan hasil tersebut yang
mendekati baku mutu sebesar 10 mg/l menurut Permen LHK No. 68 Tahun 2016
tentang air limbah domestik. Hal ini dikhawatirkan untuk pengolahan kedepan nya
IPAL tersebut tidak dapat mengolah parameter amonia sesuai baku mutu yang
ditetapkan menurut Permen LHK No. 68 Tahun 2016. Permasalahan dalam
penelitian ini adalah di Glodok Plaza Jakarta belum pernah dilakukan pengujian
Inlet pada air limbah domestik dan hanya di lakukan pengujian Outlet. Sehingga
belum bisa diketahui berapa persen efisiensi penyisihan parameter pada pengolahan
air limbah domestik. Pada penelitian ini parameter yang akan diuji terdapat 7
parameter yaitu pH, BOD, COD, amonia, TSS, Total Coliform, Minyak dan Lemak
sesuai dengan baku mutu Permen LHK No. 68 Tahun 2016 tentang air limbah
domestik. Dari hasil pengujian yang dilakukan di Laboratorium Universitas Sahid
Jakarta hasil analisis parameter yang didapatkan semua sudah memenuhi baku mutu
dan efisiensi pengolahan air limbah pada setiap parameternya masuk ke dalam
kategori efisien dan sangat efisien, diantaranya untuk parameter BOD memiliki
nilai 74,24%, COD memiliki nilai 91,57%, Amonia memiliki 98,14%, Minyak dan
Lemak memiliki nilai 93,69%, Total Coliform memiliki nilai 98,58%, dan TSS
memiliki nilai 91,39%.
Kata Kunci : Pengolahan Air Limbah Domestik, Alur Pengolahan IPAL Domestik,
Efisiensi IPAL Domestik, Uji Inlet dan Outlet Air Limbah Domestik,
Pusat Perbelanjaan.
ABSTRACT
Domestic wastewater generally derived from commercial activity or housing,
restaurants, offices, apartments, and hostels is generally produced from human
activities. Initially, Jakarta's sewage was only discharged directly into rivers or
waterways without prior treatment. This is because the sewerage system is still low,
causing the river bodies to be contaminated. (Said, 2020). The Glodok Plaza
Jakarta is located in a commercial area and is a shopping center located in the
West Jakarta region, making it one of the major domestic wastewater generators.
The domestic wastewater at Glodok Plaza comes from the toilet or laundry room,
the hotel from the bathroom and dining kitchen, and the Food Court from the food
kitchen where the wastewater is then treated so that the wastewater does not pollute
the environment. As of January 2023, the ammonia parameter has a value of 9 mg/l
based on such results which is close to the quality standard of 10 mg/L according
to Permen LHK No. 68 of 2016 on domestic wastewater. It is concerned for its
future processing the IPAL cannot process ammonia parameters in accordance
with the quality standards established according to Permen LHK No. 68 Year 2016.
The problem with this study is that at Glodok Plaza Jakarta we have not performed
an Inlet test on domestic wastewater and only an Outlet test. So it has not been
known how much the efficiency of the parameter separation on the domestic sewage
treatment is. In this study, the parameters to be tested are 7 parameters namely pH,
BOD, COD, ammonia, TSS, Total Coliform, Oils and Fats in accordance with the
standard quality Permen LHK No. 68 Year 2016 on domestic wastewater. From the
results of the testing carried out at the University of Sahid Jakarta Laboratory, the
parameter analysis results obtained all already meet the standard quality and
efficiency of wastewater treatment on each parameter falls into the category of
efficient and highly efficient, among them for the parameters BOD has a value of
74.24%, COD has the value of 91,57%, Ammonia has 98.14%, Oil and Fats has a
rating of 93.69%, Total Coliform has a score of 98.58%, and TSS has a rate of
91.39%.
Keywords : Domestic Wastewater Treatment, Domestic IPAL Treatment Pipeline,
Home IPAL Efficiency, Inlet and Home Waste Water Outlet Testing,
Shopping Center.